- Description
- Specs
EchoTrack is the lowest price, high-performance ultrasonic couplant with improved resistance to corrosion salts and is formaldehyde and glycol ether free.
Available in two viscosities, high and medium, to address most UT applications.
Operating Range: 18°F to 180°F (-8°C to 82°C) for most ambient temperature flaw detection and thickness gaging applications.
Easier removal with water wash, not film-forming.
Safety / Environment and operator friendly – no formaldehydes, nitrates, nitrites or glycol ethers.
Removal: Wipe with wet or dry paper, cloth rag or water wash.
Specification:
Viscosity:
- Standard (medium: flowable gel)
- High (stiff gel, stays in place)
pH: 8.0 nominal at 20°C
Operating Temperature: 18°F to 180°F (-8°C to 82°C)
Halogens and Sulfur: less than 50 ppm
Compliance:
- ASME Boiler & Pressure Vessel Code (T-533)
- NAVSHIPS 250-1500
- FAA-AC # 25-29 (Glycerin-free)
- Nuclear Grade (less than 50 ppm Halogens & Sulfur)
Packaging:
- ET1-MV: Medium Viscosity; 1 gallon/3.8 liter cubitainer, one refillable bottle
- ET5-MV: Medium Viscosity; 5-gallon/18.9 liter cubitainer, two bottles, dispensing faucet
- ET55-MV: Medium Viscosity; 55-gallon/208 liter drum*
- ET1-HV: High Viscosity; 1 gallon/3.8 liter cubitainer, one refillable bottle
- ET5-HV: High Viscosity; 5-gallon/18.9 liter cubitainer, two bottles, dispensing faucet
- ET55-HV: High Viscosity; 55-gallon/208 liter drum*
*Note: High Viscosity requires Echo supplied hand pump for 55-gallon drums